
Garage pedestrian door size | The Building Code Forum
Nov 24, 2025 · I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door. will that size be acceptable since it is not the main egress door?
S-1 & S-2 Regarding Parking Garage - The Building Code Forum
Jan 7, 2015 · Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage". Section 311.3 Classifies "Parking garages, open or …
Equipment Bollard in a Residential Garage - The Building Code Forum
Oct 20, 2009 · Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab. We also have two alternates that are wheel …
Garage door header space | The Building Code Forum
Aug 6, 2012 · Installation of garage door openings, where the distance (height above garage door opening) exceeds the header size, is it acceptable to put the cripple wall below the header? Still can't …
16' Garage Door Headers - The Building Code Forum
Oct 17, 2009 · Re: 16' Garage Door Headers conarb said: It's not that simple, almost all garage door headers require portal design, and usually narrow portals integrated with the header, this always …
HVAC in a garage - The Building Code Forum
Jan 12, 2012 · Codes do not permit duct openings in a residential attached garage, for obvious reasons. I ran across one yesterday where it appears that the contractor is placing an air handler in a garage …
Habitable Space Exiting into a Garage | The Building Code Forum
May 21, 2025 · The habitable space only accessed through the garage is a private hair salon, I believe this would be considered habitable space? The other rooms only accessed through the garage are a …
Garage Step and Slope - The Building Code Forum
Nov 15, 2020 · Garage floor surfaces shall be of approved noncombustible material. The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids …
2024 Portal Frames | The Building Code Forum
Apr 1, 2024 · In the picture provided, I would say that is still a single portal frame opening. I think the intent was to prevent two portal frames immediately adjacent to each other using a common header. …
Minimum Floor Slope for Drainage - The Building Code Forum
Oct 19, 2009 · Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope. It is usually 1/8” to 1/4” per foot. Here is the citation from the …